China Delivery Microcatheter Glycine™ Micro Catheter Clot Retriever Product and Devices | Ton-Bridge

Delivery Microcatheter Glycine™ Micro Catheter Clot Retriever

Short Description:

The Ton-Bridge Glycine™ Micro Catheter is designed to deliver devices with strong kink resistance and smooth navigation and it is compatible with Thombite™ Clot Retriever Device.


Product Detail

Product Tags

● Product Characteristics

·Good push-ability and strong kink resistance, easy delivery especially in complex and tortuous anatomies.

·Good compatibility, compatible with Thombite™ Clot Retriever Device and the Cylone™ Aspiration Catheter.

·Good supportability, it is based on the distal end the operation of the Glycine™ Micro Catheter provides a stable platform.

·Good lubricity, the outer hydrophilic coating is conducive to pushing in blood vessels, and PTFE lining can reduce the friction resistance of compatible devices.

·End to end stainless-steel coils provides added Radial stiffness of the Glycine™ Micro Catheter, It can ensure excellent device compatibility. Distal catheter body hydrophilic coating helps navigate tortuous vessels and reduce resistance.

·Profit from the multi segment design, the Glycine™ Micro Catheter has excellent flexibility, easy pass through tortuous blood vessels and reach M2 segment as far as possible.

● Product Use

The Glycine micro catheter is suitable for professional physician to selectively inject or input control medium and/or liquid and/or embolic meterials, and/or appropriate devices (such as clot retriever device, coils) to the periphery and neuro vasculature.

● Product Parameter

Model

Specification

Proximal OD(Fr/mm)

Distal OD(Fr/mm)

ID(in/mm)

Useable length(cm)

21

LMC-21-110

2.7/0.91

2.4/0.81

0.021/0.53

110

LMC-21-130

2.7/0.91

2.4/0.81

0.021/0.53

130

LMC-21-153

2.7/0.91

2.4/0.81

0.021/0.53

153

27

LMC-27-110

2.8/0.94

2.8/0.94

0.027/0.69

110

LMC-27-130

2.8/0.94

2.8/0.94

0.027/0.69

130

LMC-21-145

2.8/0.94

2.8/0.94

0.027/0.69

145

● Product Superiority

·It is well compatible with Thombite™ Clot Retriever Device and can improve the deployment of device.
·Distal soft tip can improve the push-ability and track-ability.
·Inner PTFE coiling lining and outer hydrophilic coating surface can significantly reduce resistance and offers smooth delivery.
·Continuous coil construction can benefit the kink resistance and enhances the navigation through tortuous anatomies.
·The distal radiopaque development marker band of the Glycine™ Micro Catheter is conducive to product navigation


  • Previous:
  • Next:

  • Write your message here and send it to us